Extractable Nuclear Antigen Antibody Pan

eD-H Order Code

LAB3611

Specimen Collection Information

Specimen Minimum Test Volume Container Special Handling
Blood 0.1 ML  

Specimen Transport Temperature

_

Reference Ranges / Critical Values

Assay Gender Age Range Normal Range Critical Values Units
Centromere Ab All 0 Minutes – 150 Years ≤10   unit/mL
Jo-1 Ab All 0 Minutes – 150 Years ≤10   unit/mL
SS-A/Ro Ab All 0 Minutes – 150 Years ≤10   unit/mL
SS-B/La Ab All 0 Minutes – 150 Years ≤10   unit/mL
Scl-70 Ab All 0 Minutes – 150 Years ≤10   unit/mL
Sm(Smith) Ab All 0 Minutes – 150 Years ≤10   unit/mL
U1RNP Ab All 0 Minutes – 150 Years ≤10   unit/mL

Specimen Stability

_

Day(s) Performed

_

CPT(s)

86235 ; 86235(x6)

Performing Lab Section

Chemistry

Intrepretive Data

Assay Interpretive Data
Centromere Ab <7 negative  7-10 equivocal  >10 positive   The CENP antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the Centromere B protein.   
Jo-1 Ab <7 negative  7-10 equivocal  >10 positive   The Jo-1 antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the Jo-1 protein.  
SS-A/Ro Ab <7 negative  7-10 equivocal  >10 positive   The SS-A antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the SS-A (Ro) protein.   
SS-B/La Ab <7 negative  7-10 equivocal  >10 positive   The SS-B antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the SS-B (La) protein.   
Scl-70 Ab <7 negative 7-10 equivocal >10 positive The Scl-70 antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the Scl-70 protein. 
Sm(Smith) Ab <7 negative  7-10 equivocal  >10 positive   The Sm antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the Sm protein.   
U1RNP Ab <5 negative  5-10 equivocal  >10 positive   The U1RNP antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the U1RNP protein.