Extractable Nuclear Antigen Antibody Pan
eD-H Order Code
LAB3611
Specimen Collection Information
Specimen | Minimum Test Volume | Container | Special Handling |
---|---|---|---|
Blood | 0.1 ML |
Specimen Transport Temperature
_
Reference Ranges / Critical Values
Assay | Gender | Age Range | Normal Range | Critical Values | Units |
---|---|---|---|---|---|
Centromere Ab | All | 0 Minutes – 150 Years | ≤10 | unit/mL | |
Jo-1 Ab | All | 0 Minutes – 150 Years | ≤10 | unit/mL | |
SS-A/Ro Ab | All | 0 Minutes – 150 Years | ≤10 | unit/mL | |
SS-B/La Ab | All | 0 Minutes – 150 Years | ≤10 | unit/mL | |
Scl-70 Ab | All | 0 Minutes – 150 Years | ≤10 | unit/mL | |
Sm(Smith) Ab | All | 0 Minutes – 150 Years | ≤10 | unit/mL | |
U1RNP Ab | All | 0 Minutes – 150 Years | ≤10 | unit/mL |
Specimen Stability
_
Day(s) Performed
_
CPT(s)
86235 ; 86235(x6)
Performing Lab Section
Chemistry
Intrepretive Data
Assay | Interpretive Data |
---|---|
Centromere Ab | <7 negative 7-10 equivocal >10 positive The CENP antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the Centromere B protein. |
Jo-1 Ab | <7 negative 7-10 equivocal >10 positive The Jo-1 antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the Jo-1 protein. |
SS-A/Ro Ab | <7 negative 7-10 equivocal >10 positive The SS-A antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the SS-A (Ro) protein. |
SS-B/La Ab | <7 negative 7-10 equivocal >10 positive The SS-B antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the SS-B (La) protein. |
Scl-70 Ab | <7 negative 7-10 equivocal >10 positive The Scl-70 antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the Scl-70 protein. |
Sm(Smith) Ab | <7 negative 7-10 equivocal >10 positive The Sm antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the Sm protein. |
U1RNP Ab | <5 negative 5-10 equivocal >10 positive The U1RNP antibody result was generated using fluoroenzyme immunoassay on the Phadia 250 analyzer. the semi-quantitative test is designed to detect IgG antibodies in human serum that are reactive to the U1RNP protein. |