Cell Count CSF
Specimen Collection Information
Specimen | Minimum Test Volume | Container | Special Handling |
---|---|---|---|
CSF | 1.5 ML |
Specimen Transport Temperature
Ambient.
Transport to Hematology Laboratory immediately.
Reference Ranges / Critical Values
Assay | Gender | Age Range | Normal Range | Critical Values | Units |
---|---|---|---|---|---|
AUTO NUC CSF CT | All | 0 Minutes – 1 Years | 0 -30 | /mcl | |
1 Years – 5 Years | 0 -20 | /mcl | |||
5 Years – 12 Years | 0 -10 | /mcl | |||
12 Years – 150 Years | 0 -5 | /mcl | |||
NUC CSF CT | All | 0 Minutes – 1 Years | 0 -30 | /mcl | |
1 Years – 5 Years | 0 -20 | /mcl | |||
5 Years – 12 Years | 0 -10 | /mcl | |||
12 Years – 150 Years | 0 -5 | /mcl | |||
Segs CSF | All | 0 Minutes – 150 Years | >90 | % |
Specimen Stability
1 hour
Interpretive Data
Assay Display | Interpretive Data |
---|---|
AUTO NUC CSF CT | If Nucleated CSF CT result equals Zero no smear is made and no Differential is performed. If Nucleated CSF CT result is 1-5 / mcL a smear is made and scanned but no results are reported unless abnormalities are noted. If Nucleated CSF CT result is 6 /mcL or greater a smear is made and manual differential is performed and reported. Nucleated CSF CT results on a CSF fluid must be correlated with clinical condition. |
NUC CSF CT | If Nucleated CSF CT result equals Zero no smear is made and no Differential is performed. If Nucleated CSF CT result is 1-5 / mcL a smear is made and scanned but no results are reported unless abnormalities are noted. If Nucleated CSF CT result is 6 /mcL or greater a smear is made and manual differential is performed and reported. Nucleated CSF CT results on a CSF fluid must be correlated with clinical condition. |
Day(s) Performed
Monday through Sunday; continuously
CPT(s)
89051
Performing Lab Section
Hematology