Sign in →

Antiphospholipid Panel

eD-H Order Code

LAB1748

Specimen Transport Temperature

Refrigerate the gold SST tubes

The Sodium Citrate tubes (blue tops) should be double spun and the plasma frozen.

Additional Specimen Instructions

2.7 mL Sodium Citrate tube filled to the line

AND

5 mL Gold SST

Collect two 2.7 mL Sodium Citrate tubes

 

 

Blue top tubes must be filled within 10% of stated volume. A discard tube must be used if a citrate tube is to be drawn using a winged blood collection set.  It is important to remove air from the blood collection set to ensure the proper blood volume is obtained in the coag tube.

 

If the patient has a known hematocrit >55%, please contact the coagulation lab for an adjusted collection tube before drawing the blood.

 

If sending an Antiphospholipid Panel from outside of the DH-H network please complete the top portion of the Antiphospholipid Panel Worksheet and include it with the specimen. A link to the worksheet can be found under the Resources section on this page.

 

 

Additional Testing Information

The antiphospholipid panel is used by rheumatologists, hematologists and other clinicians to screen high risk patients for clotting risk associated with antiphospholipid antibodies. Tests included are PT, PTT, TT, DRVVT, SCT, Anticardiolipin antibodies and Beta-2-glycoprotein-1. Results will be summarized in a pathologist interpretive report. Available in eD-H. Complete testing may take up to 10 days to complete, depending on day of specimen receipt.

CPT(s)

86147 ; 85670 ; 85670 ; 86146 ; 85610 ; 85730 ; 85610 ; 85730 ; 85613 ; 85730 ;

Performing Lab Section

Hematology